Glossary

Slowly inactivating voltage-sensitive Na and Ca currents that amplify and prolong the synaptic input to neurons. Motoneurons can have strong persistent inward currents, which are dependent on descending monoaminergic drive.

(McManus et al., 2021)

The phase of a signal denotes the delay of a periodic signal relative to a reference time point. As the value of a sinusoidal signal at any point in time is based on circular motion, the phase of a signal is expressed as an angle (start of one period = 0 degrees or 0 rad, end of one period = 360 degrees or 2π radians). The term ‘phase’ is also used in a different context to refer to regions of an action potential waveform where it deviates in either positive or negative direction.Phase difference is a measure of relative delay between two signals of the same frequency, as shown in Figure 1 of the paper attached below.

(McManus et al., 2021)

Unwanted fluctuations in voltage generated by alternating 50/ 60 Hz voltage in power lines and electrical wiring, which can contaminate or interfere with the detected EMG signal.Power line interference may also be present at higher harmonics of the 50/60 Hz AC frequency (50 – 100-150…etc. Hz or 60–120-180 etc. Hz). The magnitude of power line interference can be reduced by minimizing any difference in the electrode-tissue impedance between the two EMG amplifier input terminals through adequate skin preparation, by choosing an amplifier with a high input impedance and by moving subject and equipment away from power cables.

(McManus et al., 2021)

The average power P, in a discrete-time signal x, is defined as the mean of the squares of its sample values, as described in Formula 1. N is the total number of samples in the signal and xn is the value of the nth sample within the signal. The equation for P can also be expressed in continuous time, as expressed in Formula 2, where T is the length of the signal in seconds.

(McManus et al., 2021)
Power of a signal image
Power of a signal image

Distribution of the power contained within a signal at different frequencies. The power spectral density of an EMG signal has the units Volt squared per Hertz (V2/Hz). Related terms: Fourier transform, frequency. The integral of the power spectral density of a signal’s Fourier transform is equal to the total power of the signal.

(McManus et al., 2021)

The first stage of EMG amplification process, that is ideally located close to the electrode. Pre-amplifier should ideally have a high common mode rejection ratio (CMRR), a high input impedance, and be located close to the signal source. The purpose of the pre-amplification stage is to reject noise and interferences close to the signal source and generate a signal with a low-impedance output to help prevent further noise contamination.

(McManus et al., 2021)
Page 1 of 1
Back

We value your feedback

Let us know how helpful you found the recommendations above and how we can improve:

All A B C D E F H I M N P R S V